Follow the cover perimeter
Frame gaskets serve a different task from a circular ring: the corners, narrow legs and cover hinges can make compression uneven. Show the full frame and the mating cover, including any localized changes in gap.
- Dimension inner/outer contours and corner radii.
- Mark hinge, latch and fastener locations.
- Specify whether a seam or joint is allowed.
Decide how the frame is located
Explain whether the gasket sits in a groove, lies on a flat land or needs temporary retention during assembly. A molded section and a flat-profile frame are different design routes. The proposal should state which geometry is being evaluated.
Avoid an unsupported ingress claim
A gasket illustration cannot prove an enclosure protection level. If a water, dust or leak requirement applies, define the complete assembly test, including closures and cable penetrations, and agree the acceptance criteria.
Prepare your inquiry
- Complete perimeter and section drawing.
- Cover/lid tolerance stack and closure mechanism.
- Environmental and cleaning exposure.
- Joint, appearance and fit acceptance requirements.
Buyer questions
Is every frame gasket molded?
No. Identify whether the design calls for a flat-profile frame or a shaped molded section; the route is reviewed for the project.
Does the gasket itself have an IP rating?
An enclosure rating depends on the complete assembled product and its test conditions. It should not be inferred from a loose gasket.
Related project families
Engineering reading
General references and scope
These references explain general engineering or regulatory context. They are not Xinwei finished-product specifications, test results or compliance evidence.